Table of Contents
- 1 What is the use of cooling tubes in transformer?
- 2 What is the maximum range the natural oil cooling can be used in a transformer?
- 3 Which of the following methods is used for cooling of transformers up to a capacity of 10 MVA?
- 4 Which cooling method is used in pole mounting distribution transformer?
What is the use of cooling tubes in transformer?
What is Cooling Tubes in Transformer? : These Cooling Tubes provide better and effective cooling of transformer oil by increasing the surface area of tank to the atmosphere.
Which type of cooling is used for large transformer?
Oil Forced Water Forced (OFWF) This type of cooling is used in very large transformers having rating of several hundreds MVA.
What is cooling of transformer?
When the transformer is in operation, heat is generated due to copper losses in the windings and iron losses in the core. The removal of heat from the transformer is known as cooling of the transformer.
What is the maximum range the natural oil cooling can be used in a transformer?
Oil natural and air natural method is used for transformer rating up to 30 MVA. Oil natural and air forced method of cooling can be used up to 60 MVA.
How many cooling system does a transformer have?
The following two transformer cooling methods are adopted in dry-type transformers. Air Natural (AN) cooling – Cooled by surrounding air. Heat transfer by natural convection. Air Forced (AF) cooling – Forced sir circulation using fans and blowers.
What is the function of radiator in transformer?
The radiator of transformer accelerates the cooling rate of transformer. Thus, it plays a vital role in increasing loading capacity of an electrical transformer. This is basic function of radiator of a power transformer.
Which of the following methods is used for cooling of transformers up to a capacity of 10 MVA?
For transformers upto a capacity of kVA air blast cooling is provided. 213.
What type of cooling is being made use of in transformers having a capacity of less than 11MVA?
natural cooling
What type of cooling is being made use of in transformers having a capacity of less than 11MVA? Explanation: For transformers having capacity less than 11MVA, natural cooling is made use of. For transformers having capacity more than 11MVA, air blast cooling is used. 4.
What type of cooling is being made use of in transformers having a capacity of less than 11MVA Mcq?
What type of cooling is being made use of in transformers having a capacity of less than 11MVA? Explanation: For transformers having capacity less than 11MVA, natural cooling is made use of. For transformers having capacity more than 11MVA, air blast cooling is used. 4.
Which cooling method is used in pole mounting distribution transformer?
Natural convection process is used for this type of cooling. The assembly of the core and windings are placed in the oil-immersed tank. As the core and the windings heat up the temperature of the oil in the transformer rises. As a result, the oil moves upward and flows from the upper portion of the transformer tank.
What is radiator substation?
Radiator is a bank of hollow pipe line which is used to transfer the thermal energy from one medium to another for the purpose of cooling. Some Bank are used at the power transformer for cooling the transformer oil as well as reduces the winding temperature under loading condition.
What is increased in step up transformer?
The step-up transformer increases the output voltage and the step-down transformer decreases the output voltage. The step-down transformer decreases the voltage from the primary to the secondary coil. It converts high voltage, low current power into low voltage high current power.