Table of Contents
Can a centrifugal pump running with discharge valve closed?
If the discharge valve is closed and there is no other flow path available to the pump, the impeller will churn the same volume of water as it rotates in the pump casing. If the pump is run in this condition for a significant amount of time, it will become damaged.
What has to be considered when a pump has to be started with open discharge valve?
If you start the pump with discharge valve open, the discharge head will act on the pump ie, more resistance, so the motor has to give more starting torque to the pump which means more current is drawn by the motor. It can also be prevented by keeping the discharge valve closed.
Why priming is done before starting a centrifugal pump?
Priming of a centrifugal pump is the process of filling the liquid at the suction pipe and the impeller. Priming is done to put pump into working order by filling or charging with water. Why Priming is required? This pressure will not suck water from its source through the suction pipe.
Which type of pump should never be started with the discharge closed?
multistage pumps must never be operated with the discharge valve closed.
How do you start a centrifugal pump?
Centrifugal pump start up procedure
- Open the suction valve.
- Open any recirculation or cooling lines.
- Fully close or partially open the discharge valve, depending on system conditions.
- Start the driver.
- Slowly open the discharge valve until the pump reaches the desired flow.
How do you start and stop a centrifugal pump?
When a centrifugal pump is started How is the delivery valve kept?
The delivery valve connects the pump outlet and the delivery pipe. It remains closed before the pump is switched on. When the pump builds up its pressure, it is opened and can be used to control or vary the discharge.
How can you prevent priming in a centrifugal pump?
Consider using a foot valve and an outside source of liquid in order to prime the pump.
- Close the discharge isolation valve.
- Open the air vent valves in the casing.
- Open the valve in the outside supply line until only liquid escapes from the vent valves.
- Close the vent valves.
- Close the outside supply line.
Are Centrifugal pumps self priming?
However, standard centrifugal pumps are not designed to be self-priming. With centrifugal pumps, the pumping action occurs when an impeller is rotated in a liquid within a cavity or chamber of the pump, displacing the liquid and forcing it to flow into the discharge port of the pump via centrifugal force.
When starting a centrifugal pump the delivery valve is kept *?