Table of Contents
- 1 What are sources of error in meter bridge experiment?
- 2 What are the errors in meter bridge?
- 3 What are the sources of errors in this experiment?
- 4 What are the sources of errors in bridge circuits give the precautions & techniques to reduce errors?
- 5 What is the end error in Metre bridge How is it overcome?
- 6 What are the types of experimental errors?
- 7 Which error of Metre bridge is removed?
What are sources of error in meter bridge experiment?
Sources of error and their minimisation in meter-bridge : (1) Error due to non-uniformity of wire: Due to non-uniformity of wire, resistance per unit length of wire is not uniform and accordingly null point is not obtained correctly. Correction : To minimize this error, wire must be of uniform cross-section.
What are the errors in meter bridge?
The zero of the scale may not start from the point where the bridge wire is connected to the copper strip and 100 cm on the scale may not coincide with the position where the bridge wire touches the copper strip. (ii) Error may be caused by the resistance of the metre bridge wire and the copper strip.
What are the sources of errors in this experiment?
Common sources of error include instrumental, environmental, procedural, and human. All of these errors can be either random or systematic depending on how they affect the results. Instrumental error happens when the instruments being used are inaccurate, such as a balance that does not work (SF Fig.
What are the sources of measurement errors in a Wheatstone bridge?
Kelvin bridge is used for the measurement of low resistance. Explanation: The main source of error in a Wheatstone bridge is because of the limiting errors of the three known resistances. As a result very precise resistances are required with 1 \% tolerance.
What are the possible errors of a Metre bridge and how can they be removed?
End error can be removed by repeating the experiment by interchanging unknown and known resistance and finally taking the mean value of resistance obtained in each experiment.
What are the sources of errors in bridge circuits give the precautions & techniques to reduce errors?
Error due to sliding of jockey on the wire.
What is the end error in Metre bridge How is it overcome?
End error in a meter bridge is an error caused due to the shifting of zero of the scale at different points due to non-uniformity of metal wire. The end error can be overcome by repeating the experiment by interchanging unknown and known resistance and taking the mean value of resistance obtained in each experiment.
What are the types of experimental errors?
There are two types of experimental errors: systematic errors and random errors. Systematic errors are errors that affect the accuracy of a measurement.
What causes errors in meter bridge experiment to minimize these errors?
a. Error due to sliding of jockey on the wire:- Due to sliding of the jockey, heat is produced due to friction. Thus the area of wire can be deformed and resistance of the wire may change. To minimise this error, jockey is tapped on the wire.
Which error of Metre bridge is removed when the known and unknown resistance are interchanged?
The error created due to this is called end error. To remove this the resistance box and the unknown resistance must be interchanged and then the mean reading must be taken.
Which error of Metre bridge is removed?
The best I can explain: End error is removed when the known and unknown resistances are interchanged in a Meter Bridge.
https://www.youtube.com/watch?v=yN_lWMwnMlY